AT6101C, AT6101CM Spectrometers
AT6101C, AT6101CM Spectrometers
-
Best in class
-
20 hours of operation time
-
Automatic simultaneous gamma and neutron radiation scanning with radionuclide identification
-
Continuous recording of scanning data with GPS referencing for further analysis
-
Dose rate measurement range can be expanded to 10 Sv/h
-
"GARM" application software for further data processing and analysis in expert mode
Applications
|
AT6101С
|
AT6101СМ
|
Gamma radiation detection units, scintillation detector
|
BDKG-11M (1 or 2 units),
NaI(Tl) Ø63x63 mm |
BDKG-19M (1 or 2 units),
NaI(Tl) Ø63x160 mm |
Energy range
|
20 keV – 3 MeV
|
|
Measurement range of ambient dose equivalent rate
|
0.03 – 150 µSv/h
|
0.03 – 50 µSv/h
|
Limits of tolerable intrinsic relative error
|
±20%
|
|
Typical sensitivity to 137Cs gamma radiation
|
2200 cps/(µSv·h-1)
[4400 cps/(µSv·h-1)]* |
6000 cps/(µSv·h-1)
[12000 cps/(µSv·h-1)]* |
Detectable activity of 137Cs source, moving at the speed of 0.6 m/s and located at the distance of 1 m in a time not longer than 2 s (95 % probability of source detection with false alarm rate not above 1 in 10 min)
|
400 kBq
[280 kBq]* |
250 kBq
[170 kBq]* |
Alarm activation time
|
<2 s
|
|
Typical resolution at 662 keV (137Cs)
|
7.5%
|
8%
|
Identified radionuclides
(Library contents can be modified on request) |
Industrial, natural, medical
|
|
Option to extend the dose rate measurement range
|
BDKG-04 detection unit, up to 10 Sv/h
|
|
|
||
Neutron radiation detection unit, detector
|
BDKN-05M**, Two Не-3 proportional counters Ø30x360 mm in polyethylene moderator
|
|
Energy range
|
0.025 eV – 14 MeV
|
|
Typical sensitivity to 252Cf neutron radiation
|
20 cps/(neutron·s-1·cm-2)
|
|
Detectable activity of Pu-Be source, located at the distance of 1.25 m in a time not longer than 3 s (95 % probability of source detection with false alarm rate not above 1 in 1 h)
|
(5.00±1.25)∙104 neutron/s
|
|
Protection class
|
IР55 (backpack)
IР65 (case) |
|
Overall dimensions, weight ***
|
520х380х220 mm, 7 kg (backpack)
625х500х300 mm, 16.5 kg (case) |
550х340х220 mm, 9 kg (backpack)
625х500х300 mm, 18 kg (case) |
* Configuration with two BDKG-11M (BDKG-19) detection units
** Not available for configuration with two BDKG-11M (BDKG-19) detection units *** Configuration with BDKG-11M (BDKG-19M) and BDKN-05M detection units |
Design and specifications are subject to change.
For details see our datasheet.
Specifications
Gamma radiation detection unit, detector: |
Energy range: |
Measurement range of ambient dose equivalent rate: |
Typical sensitivity to 137Cs gamma radiation: |
Minimal detectable level of gamma radiation dose rate from a source, travelling at the speed of 0.5 m/s: |
Minimal detectable activity of 137Cs source, located at the distance of 1 m in a time not longer than 2 s. (95% probability of source detection with false alarm rate not above 1 in 10 min.): |
Alarm response time: |
Typical energy resolution at 662 keV (137Cs): |
Identified radionuclides (The library content can be modified on request): |
|
Option to extend the dose rate measurement range: |
|
Neutron radiation detection unit, detector: |
Energy range: |
Typical sensitivity to 252Cf neutron radiation: |
Minimal detectable activity of Pu-Be source, located at the distance of 1.25 m in a time not longer than 3 s. (95% probability of source detection with false alarm rate not above 1 in 1 h): |
|
Overall dimensions / weight ***: |
* Version with two BDKG-11M (BDKG-19) detection units |