AТ6110 Radiation Portal Monitor (rapid deployable)
AТ6110 Radiation Portal Monitor (rapid deployable)
Detects sources of gamma and neutron radiation in vehicles, cargo and pedestrian traffic.
- Rapid deployment
- High sensitivity
- Categorization of radiation sources into natural and artificial
- Up to 20 h of operation time on built-in batteries
- Storage and operation in rugged cases
- Severe operating conditions
Applications
Monitor configuration
|
Gamma channel: 1 x BDRM-05
Neutron channel: 2 x BDKN-05 |
Total number of monitors in the system
|
Up to 8
|
Time of continuous operation
|
~20 h
|
Monitors power supply
|
Built-in rechargeable battery pack
|
Protection class
|
IР55
|
Dimensions and weight of monitor attached to frame (in operating position)
|
2090x1025x955 mm, 78 kg
|
Gamma radiation detection units
|
BDRM-05
|
Scintillation detector
|
Plastic, 1000х100х50 mm
|
Energy range
|
50 keV – 3 MeV
|
Typical sensitivity to source radiation, cps/(µSv·h-1)
|
60000 [241Am]
32000 [137Cs] 17000 [60Co] |
Neutron radiation detection units
|
BDKN-05
|
Detector
|
Two He-3 proportional counters in polyethylene moderator
|
Energy range
|
0.025 eV – 14 MeV
|
Typical sensitivity to source radiation at the distance of 1 m, cps/(neutron·s-1·cm-2)
|
20 [252Cf]
|
Detection threshold for unshielded source
under natural radiation background conditions not more than 0.1 µSv/h (Probability of source detection 80% under confidence level Р=0.95) |
||||
Road vehicles. Travel speed 8 km/h
|
||||
|
Monitors configuration (location and number)
|
Gamma channel
|
Neutron channel
|
|
Detection
|
Categorization
|
|||
Control zone
width – 3 m, height – 2 m |
|
940 kBq [241Am]
130 kBq [137Cs] 70 kBq [60Co] |
1100 kBq [241Am]
310 kBq [137Cs] 330 kBq [60Co] |
2.1∙104 neutron/s [252Cf]
|
|
690 kBq [241Am]
100 kBq [137Cs] 50 kBq [60Co] |
800 kBq [241Am]
240 kBq [137Cs] 250 kBq [60Co] |
1.2∙104 neutron/s [252Cf]
|
|
Control zone
width – 6 m, height – 4.5 m |
|
2140 kBq [241Am]
290 kBq [137Cs] 150 kBq [60Co] |
2500 kBq [241Am]
690 kBq [137Cs] 710 kBq [60Co] |
2.2∙104 neutron/s [252Cf]
|
|
1570 kBq [241Am]
210 kBq [137Cs] 110 kBq [60Co] |
1900 kBq [241Am]
500 kBq [137Cs] 520 kBq [60Co] |
1.4∙104 neutron/s [252Cf]
|
Design and specifications are subject to change.
For details see our datasheet.
Specifications
Gamma radiation detection units: |
Scintillation detector: |
Energy range: |
Typical sensitivity to source radiation: |
|
Source detection threshold under conditions of natural radiation background not above 0.1 µSv/h (Probability of source detection is 80% (50%*) under confidence level Р=0.95). |
|
Neutron radiation detection units: |
Detector: |
Energy range: |
Typical sensitivity to source radiation at the distance of 1 m: |
|
Source detection threshold (Probability of source detection is 90% (50%*) under confidence level Р=0.95). |
|
Total number of monitors in the system: |
Time of continuous operation: |
Monitors power supply: |
Protection class: |
Dimensions and weight of monitor attached to frame (in operating position) |