AТ2341 Radiation Monitoring Station
AТ2341 Radiation Monitoring Station
Combine stations into a single network (up to 256 units) and use dedicated software to build an automated radiation situation monitoring system.
▪ High-sensitive spectrometric measurement channel
▪ Simultaneous monitoring of radiation and weather data
▪ Redundant power supply for at least 72 hours operation time
▪ Communication links: Cellular (3G, 4G, 5G); Ethernet; Wireless; Wi-Fi
Applications
Protection rating
|
IР65 (IP66 for weather station)
|
Operation temperature range
|
-40...+50°С
|
Relative air humidity
|
≤98% (Air temperature
≤35оС without condensation) |
Dimensions
|
800х600х300 mm
|
Weight
|
≤45 kg
|
SPECTROMETRIC CHANNEL
|
|
Detection unit
|
BDKG-211M
|
Detector
|
NaI(TI) scintillator, ø63x63 mm
|
Energy range
|
20 keV – 3 MeV
|
Measurement range of ambient dose equivalent rate
|
30 nSv/h – 150 µSv/h
|
Limits of tolerable intrinsic relative error
|
±20%
|
Energy dependence relative to 662 keV (137Cs)
|
±20% (40 keV – 3 MeV)
|
Typical sensitivity to gamma radiation, cps/(µSv·h-1)
|
13900 (241Am) / 2450 (137Cs) / 1300 (60Co)
|
Response time for dose rate change from 0.1 to 1 µSv/h
|
≤2 s
|
Typical resolution at 662 keV (137Cs)
|
7.5%
|
DOSIMETRIC CHANNEL (available options)
|
||
Detection unit
|
BDKG-22
|
BDKG-224
|
Detector
|
Geiger-Muller
counter tube
|
Tissue-equivalent scintillation
plastic, Ø50x40 mm
|
Energy range
|
60 keV – 3 MeV
|
30 keV – 10 MeV
|
Measurement range of ambient dose equivalent rate
|
100 nSv/h – 10 Sv/h
|
40 nSv/h – 1 Sv/h
|
Limits of tolerable intrinsic relative error
|
±20%
|
±20%
|
Energy dependence relative to 662 keV (137Cs)
|
-25% to +35%
(60 keV – 3 MeV) |
±25% (30 keV – 3 MeV)
±40% (3 – 10 MeV)
|
Typical sensitivity to gamma radiation, cps/(µSv·h-1)
|
4 (241Am)
4 (137Cs) 4 (60Co) |
3200 (241Am)
530 (137Cs) 270 (60Co) |
Response time for dose rate change from 0.1 to 1 µSv/h
|
≤7 s
|
≤2 s
|
Design and specifications are subject to change.
For details see our datasheet.
Specifications
AТ2341 Radiation Monitoring Station
|
Protection rating
IР65 (IP66 for weather station) |
Operation temperature range
-40...+50°С |
Relative air humidity
≤98% (Air temperature ≤35оС without condensation) |
Dimensions
800х600х300 mm |
Weight
≤45 kg |
SPECTROMETRIC CHANNEL
|
Detection unit BDKG-211M
|
Detector
NaI(TI) scintillator, ø63x63 mm |
Energy range
20 keV – 3 MeV |
Measurement range of ambient dose equivalent rate
30 nSv/h – 150 µSv/h |
Limits of tolerable intrinsic relative error
±20% |
Energy dependence relative to 662 keV (137Cs)
±20% (40 keV – 3 MeV) |
Typical sensitivity to gamma radiation, cps/(µSv·h-1)
13900 (241Am) / 2450 (137Cs) / 1300 (60Co) |
Response time for dose rate change from 0.1 to 1 µSv/h
≤2 s |
Typical resolution at 662 keV (137Cs)
7.5% |
DOSIMETRIC CHANNEL (available options)
|
Detection unit
Geiger-Muller counter tube (BDKG-22) |
Energy range
60 keV – 3 MeV (BDKG-22) |
Measurement range of ambient dose equivalent rate
100 nSv/h – 10 Sv/h (BDKG-22) |
Limits of tolerable intrinsic relative error
±20% |
Energy dependence relative to 662 keV (137Cs)
-25% to +35% (60 keV – 3 MeV) (BDKG-22) |
Typical sensitivity to gamma radiation, cps/(µSv·h-1)
4 (241Am) / 4 (137Cs) / 4 (60Co) (BDKG-22) |
Response time for dose rate change from 0.1 to 1 µSv/h
≤7 s (BDKG-22) |