AT6103 Mobile Radiation Scanning System
AT6103 Mobile Radiation Scanning System
- User-selectable set of smart detection units
- High system scalability in terms of sensitivity to gamma and neutron radiation
- Automatic simultaneous gamma and neutron radiation scanning
- Real-time display of measurement results with GPS referencing
- Search and detection of radioactive sources and real-time identification of its isotopic composition
- Storage and operation in rugged cases
- Assessment of surface contamination with 137Cs radionuclide (kBq/m2, Ci/km2)
Available monitors
[Each monitor may contain 1 – 3 detection units]
[The configuration of the system is user-defined]
|
1) Gamma radiation and neutron radiation monitor [1 – 3 units of BDKG -11M and/or BDKG-19M, 1 – 3 units of BDKN-05, 1 unit of BDKG-04] 2) Highly-sensitive gamma radiation and neutron radiation monitor [1 – 3 units of BDKG-28 and/or BDKG-34, 1 – 2 units of BDKN-05, 1 unit of BDKG-04] 3) Highly-sensitive gamma radiation and neutron radiation counting monitor [1 – 2 units of BDRM-05, 1 – 2 units of BDKN-05, 1 unit of BDKG-04] |
Total number of monitors in the system
|
18
|
Identified radionuclides
|
Medical, industrial and natural
(The library content can be modified on request)
|
The system in "Search" mode detects gamma radiation source containing 137Cs in less than 2 s in the following conditions:
|
|||||
Gamma radiation detection unit
|
BDKG-11M
|
BDKG-19М
|
BDKG-28
|
BDKG-34 |
BDRM-05
|
Source activity
|
(450±10) kBq
|
(300±10) kBq
|
(105±5) kBq
|
(105±5) kBq |
(100±5) kBq
|
Distance from source to surface of detection unit
|
(100.0 ± 0.5) cm
|
||||
Detection probability
|
95%
|
||||
False alarm rate
|
≤1 / 10 min
|
The system in "Search" mode detects Pu-Be source of neutron radiation in less than 3 s in the following conditions:
|
|
Neutron radiation detection unit
|
BDKN-05
|
Average neutron flux from source to solid angle 4 π, sr
|
(5.00±1.25)∙104 neutron∙s-1
|
Distance from source to surface of detection unit
|
(125±1) cm
|
Detection probability
|
95%
|
False alarm rate
|
≤1 / 1 h
|
Design and specifications are subject to change.
For details see our datasheet.
Specifications
Available monitors for the system: 1) Gamma radiation and neutron radiation monitor [Each monitor may contain 1 – 3 detection units] |
Total number of monitors in the system: |
Identified radionuclides: |
|
The system in "Search" mode detects gamma radiation source containing 137Cs in less than 2 s in the following conditions: |
|
The system in "Search" mode detects Pu-Be source of neutron radiation in less than 3 s in the following conditions: |