AT1117M Radiation Monitor (Transportable dosimetric monitoring stations)
AT1117M Radiation Monitor (Transportable dosimetric monitoring stations)
The following configurations of radiation monitor can be used:
With BDKG-24: For measurement of gamma and X-ray radiation ambient dose equivalent and ambient dose equivalent rate
With BDKG-30: For measurement of air kerma and air kerma rate
- High sensitivity
- Sound, light and visual alarm for exceeded threshold levels
- Can be operated both as fixed and portable instrument
- Automatic recording and storage over 10,000 measurements with GPS referencing information, when PU4 is used
- Automatic data transfer to a remote server, as well as processing in an export application software, when PU4 is used
Version 1
|
Version 2
|
Version 3
|
▪ BDKG-24 or BDKG-30 Detection units
▪ PU2 Processing unit ▪ Cable ▪ Tripod with a bracket |
▪ BDKG-24 or BDKG-30 Detection units
▪ PU4 Processing unit ▪ BT-DU4 Adapter ▪ Tripod with a bracket |
▪ BDKG-24 or BDKG-30 Detection units
▪ PU4 Processing unit ▪ Cable ▪ Tripod with a bracket |
Processing unit
|
PU2 (Version 1)
|
PU4 (Version 2, 3)
|
Measurement range of ambient dose equivalent rate
|
1 µSv/h – 100 mSv/h
|
1 µSv/h – 100 mSv/h
|
Overall dimensions, weight
|
210х88х36 mm, 0.6 kg
|
265х90х40 mm, 0.6 kg
|
Detection unit*
|
BDKG-24
|
BDKG-30
|
Detector
|
Scintillation plastic, Ø50x40 mm
|
|
Energy range
|
25 keV – 10 MeV
|
50 keV – 10 MeV
|
Measurement range of ambient dose equivalent rate
|
30 nSv/h – 1 Sv/h
|
–
|
Measurement range of air kerma rate
|
–
|
30 nGy/h – 1 Gy/h
|
Typical sensitivity to 137Cs gamma radiation
|
530 cps/(µSv∙h-1)
|
600 cps/(µGy·h-1)
|
Overall dimensions, weight
|
Ø60x205 mm, 0.5 kg
|
Ø60x207 mm, 0.6 kg
|
* BDKG-24 (BDKG-30) detection unit can be replaced by any detection unit from АТ1117М radiation monitor set (except BDKN-03, BDKN-05)
|
Design and specifications are subject to change.
For details see our datasheet.
Specifications
Processing unit: PU2 (Version 1) |
Measurement range of ambient dose equivalent rate : |
Overall dimensions / weight: |
|
Detection unit: BDKG-24/BDKG-30 |
Scintillation detector: |
Energy range: |
Measurement ranges: |
Typical sensitivity to 137Cs gamma radiation : |
Overall dimensions / weight: |